Fig 803 Ribbed Insulation Protection Shield

“APPLICATION: Fig. 803 Ribbed Insulation Protection Shields are used to distribute a concentrated support load over a larger area and thereby prevent the crushing of insulation at the support point. The ribs in a Fig. 803 Ribbed Insulation Protection Shield are intended to provide resistance against the hanger strap moving along the length of the shield.
CONSTRUCTION: Depending upon the outside diameter of the insulated piping, the shield is rolled from carbon steel ranging in thickness from 12 gauge to 18 gauge.
ALTERNATIVES: AAA Technology offers Urethane Pipe Saddles, TRI*FOAM supports, as well as machined Wood Blocks, TRI*CAL supports, for the support of chilled water and refrigeration piping. Contact AAA Technology for details.
FINISHES AVAILABLE: Black, Hot Dip Galvanized, Electro-Plated or Painted.
ORDERING: Specify figure number, exact outside diameter of insulated line by length of shield desired, name and finish, if other than black.
EXAMPLE: Fig. 803, 8.625” Dia. X 12” long, Ribbed Insulation Protection Shield, Electro-Plated.”

Fig 803 Ribber Insulation Protection Shield DIM

Ribbed Insulation Protection Shield

Fig 803 Ribbed Insulation Protection Shield

SHIELD SIZESHIELD ID "A" (IN)SHIELD THK. "T" (IN)SHIELD LENGTH "L" (IN)SPACING BETWEEN RIBS (IN)WT EA
12.3818 ga.820.44
22.6218 ga.820.49
32.8818 ga.820.52
43.5018 ga.820.63
54.0018 ga.820.72
64.5018 ga.820.8
75.0018 ga.820.9
85.5618 ga.821
96.0018 ga.821.08
106.6318 ga.1221.2
117.6518 ga.1222.05
128.6318 ga.1822.3
139.6318 ga.1822.2
1410.7518 ga.2422.9